LT Switchgear — ACB, MCCB, MPCB & Contactors
Air circuit breakers, moulded-case and motor-protection breakers, contactors and overload relays for incomers, feeders and motor circuits.
Air and moulded-case breakers, contactors, protection relays and surge protection — selected against your fault level and coordinated so the right device trips first.
Switchgear selection is a coordination exercise, not a catalogue pick. We work from the fault level at the point of installation, choose breaking capacity and utilisation category to match, and set discrimination so a downstream fault does not take out the incomer.
We supply loose switchgear against a schedule, or fit and wire it inside panels we build. Agricultural pump-set starters and protection run on the same line card.
Air circuit breakers, moulded-case and motor-protection breakers, contactors and overload relays for incomers, feeders and motor circuits.
Electromechanical and electronic relays for circuit protection, interlocking and control logic, including motor and phase-fault protection.
Transient surge suppression at the incomer and at sensitive sub-boards, protecting drives, PLCs and instrumentation from spikes.
Pump-set starters and protection built for agricultural supply conditions — wide voltage swing, single-phasing and dry-run risk.
Manual and motorised changeover switches, load-break isolators and on-load switch disconnectors for source selection and safe isolation.
Residual-current devices and earth-leakage relays with core-balance CTs for personnel and fire protection on distribution circuits.
| General rules | IEC 60947-1 |
|---|---|
| Circuit breakers | IEC 60947-2 — Icu / Ics rated to the project fault level |
| Contactors & starters | IEC 60947-4-1, utilisation categories AC-1 and AC-3 |
| Starter coordination | Type-1 or Type-2 to IEC 60947-4-1, as specified |
| Surge protection | IEC 61643-11 — Type 1 and Type 2 SPDs |
| Enclosure protection | IP42–IP54 indoor · IP55 outdoor |











Type-1 permits contactor and starter damage after a short circuit provided there is no hazard outside the enclosure; Type-2 permits only light contact welding, so the starter stays serviceable. Type-2 costs more and is normally specified for critical or hard-to-reach drives. Tell us the duty and we will quote the coordinated combination.
Type 1 at the origin of the installation where a direct lightning strike is credible, Type 2 at distribution boards feeding sensitive equipment. Many sites need both, coordinated by cable length or a decoupling inductor.
Yes. We supply against your schedule as an authorised channel promoter for the brands listed, so warranty and manufacturer support carry through.